- Name:LES-01 Light Quality Assessment System
- Model:LES-01
- Brand:ULIKE
- Describe:LES-01 LightQuality Assessment System is an efficient and high-precision platform thataimed at LED photobiological radiation safety test and assessment. Itintegrated scientific CCD ...
TEL:15858287688
Summary
Parameter
Application
Download
LES-01 Light
Quality Assessment System is an efficient and high-precision platform that
aimed at LED photobiological radiation safety test and assessment. It
integrated scientific CCD 2-D luminance test system, high-precision and high
dynamic range array spectral radiation analyzer, 16 bit high-precision
instantaneous digital photometer. This system with TONGSHANG LesPro special t
software can analyze and test photobiological safety parameters of lighting LED
accurately and quickly and assess the level of photobiological safety class.
Advantages and
Characteristics:
1) Professional:
aimed at characteristics of lighting LED, according to latest requirements of
IEC/EN62471、IEC62471-2、IEC62778、GBT20145
2) Overall:
provide spectral irradiance, spectral radiance, apparent luminance,
instantaneous optical properties integration solutions
3) Detailed:
More than megapixels resolution high-precision and high sensitivity scientific
CCD, Hamamatsu original import sensor, high-precision 16 bit ADI professional
ADC
4) Efficient:
time-consuming of measurement no more than 40s
5) Patent
technology, independent research and development
Technical:
1) Uncrossed
C-T construction high-precision array spectral testing platform
2) Spectral
Range: 300nm-700nm
3) Testing
Spectral Interval: 1nm
4) Wavelength
Accuracy: 0.3nm
5) High Testing
Dynamic Range: 100,000:1
6) Scientific
2-D Area CCD: More than megapixels resolution 1360×1200, pixel size 6.5μm×6.5μm
7) Testing
Caliber: 7mm, meet all the lighting requirements
8) Testing
Angle of Vision: including 100mrad,11mrad,1.7mrad,
meet standard requirements
9) Instantaneous
Testing Characteristics: quick sampling in 2μs, ADI original 16 bit
high-precision and high-resolution ADC
10) Pulse emitting test is
supported.
1) IEC62471 series standards,
GB/T 20145-2006, lighting products photobiological hazard basic standard.
Les-01 Light Quality Assessment series
with optional 200-3000nm spectroradiometer, optical guide, standard light source
can test actinic-UV exposure hazard for skin and eyes, near-UV exposure hazard
for eyes, retinal blue light exposure hazard, retinal thermal exposure hazard,
thermal exposure hazard for eyes, thermal exposure hazard for the skin, etc.
2) IEC62778 Blue Light Hazard
Assessment
Execute requirements of IEC62778,
LES-01 Light Quality Assessment System can test LED radiance or irradiance
to evaluate lamps’ RG0/RG1/RG2 (Ethr) classification.
3) Photometric Flicker
automatic test